DongHyeonkaandClaude Opus 5 4177fb6a48 docs: A-2 — losing the database takes every node down while up stays 1
Both pods go NotReady, the Service endpoint list empties and the front door returns 503, so adding Keycloak replicas buys nothing against database loss. The node holding the session in cache fails too, because a refresh writes LAST_SESSION_REFRESH. Recovery was automatic in about fifteen seconds with no restart, which is what readiness rather than liveness buys.

The observability finding matters as much: up stayed at 1 through a total outage, so alerting on it would have caught nothing. kube-state-metrics is missing and pod readiness is therefore not recorded as a metric.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-04 11:57:55 +09:00
..